-- Network Working Group K. Tesink
-- Request for Comments: 2558 Telcordia Technologies
-- Obsoletes: 1595 March 1999
-- Category: Standards Track-- Definitions of Managed Objects
-- for the SONET/SDH Interface TypeSONET-MIB DEFINITIONS::=BEGINIMPORTSMODULE-IDENTITY,OBJECT-TYPE,Integer32, transmission
FROM SNMPv2-SMI
DisplayString,TruthValueFROM SNMPv2-TC
MODULE-COMPLIANCE,OBJECT-GROUPFROM SNMPv2-CONF
ifIndex
FROM IF-MIB
PerfCurrentCount,PerfIntervalCountFROM PerfHist-TC-MIB;-- This is the MIB module for the SONET/SDH Interface objects.sonetMIB MODULE-IDENTITYLAST-UPDATED"9810190000Z"
ORGANIZATION"IETF AToM MIB Working Group"CONTACT-INFO"Kaj Tesink
Telcordia Technologies
Tel: (732) 758-5254
Fax: (732) 758-2269
E-mail: kaj@research.telcordia.com."DESCRIPTION"The MIB module to describe
SONET/SDH interfaces objects."REVISION"9810190000Z"DESCRIPTION"The key changes made to this MIB module
since its initial publication in RFC 1595
are as follows.
(1) The MODULE-IDENTITY has been updated to reflect the
changes to the MIB.
(2) Where applicable, the textual conventions
PerfCurrentCount and PerfIntervalCount from
PerfHist-TC-MIB have been used in place of Gauge32.
(3) An agent now has the option to delay updates to
the various performance counts in lieu of performing
retroactive adjustments upon entering into or exiting
from unavailable time. This implementation option is
described in Appendix A of this memo.
(4) In order to make the SONET-MIB more useful for
circuit provisioning, the formerly read-only objects
sonetMediumType, sonetMediumLineCoding,
sonetMediumLineType, and sonetMediumCircuitIdentifier
have been given a MAX-ACCESS of read-write. The
MIN-ACCESS remains read-only.
(5) The DESCRIPTION clause for sonetMediumTimeElapsed has
been updated to describe its behaviour if the duration
of the current interval exceeds the maximum value.
(6) The DESCRIPTION clause for sonetMediumValidIntervals
has been updated to describe its behaviour when some
intervals may be unavailable, and the object
sonetMediumInvalidIntervals has been added to keep
count of the number of missing intervals (if any).
(7) The object sonetMediumLoopbackConfig has been added
to enable or disable loopback configurations.
(8) Because the error count thresholds for declaring
severely errored seconds that are specified in ANSI
T1.231-1993, ITU-T G.826-1995, and ANSI T1.231-1997
are all different from each other and from the thresholds
specified in RFC 1595, an enumerated INTEGER object
sonetSESthresholdSet has been added to allow an agent
to specify which threshold set is in use. Text has
been added to Section 3 stating that if this object is
not implemented the thresholds specified in RFC 1595
should be assumed, and the table containing those
thresholds has been moved to Appendix B of this memo.
(9) A column with SYNTAX TruthValue has been added to each
interval table. The purpose of the additional column
is to indicate, for each interval, whether the data
is valid in the sense intended by ANSI T1.231 clause
9.1.2.2 [31][35]. The objects in question are:
sonetSectionIntervalValidData
sonetLineIntervalValidData
sonetFarEndLineIntervalValidData
sonetPathIntervalValidData
sonetFarEndPathIntervalValidData
sonetVTIntervalValidData
sonetFarEndVTIntervalValidData
(10) The ranges for sonetPathCurrentStatus and
sonetVTCurrentStatus have been made consistent
with the DESCRIPTION clauses.
(11) The conformance information has been updated. Previous
conformance information from RFC 1595 has been
deprecated. Some typographical errors in the deprecated
section have been corrected in order to prevent
MIB compilation errors."REVISION"9401030000Z"DESCRIPTION"The RFC1595 version of this MIB module."::={ transmission 39}-- This is the MIB module for the SONET/SDH objectssonetObjects OBJECTIDENTIFIER::={ sonetMIB 1}sonetObjectsPath OBJECTIDENTIFIER::={ sonetMIB 2}sonetObjectsVT OBJECTIDENTIFIER::={ sonetMIB 3}-- groups in the SONET/SDH MIB modulesonetMedium OBJECTIDENTIFIER::={ sonetObjects 1}
sonetSection OBJECTIDENTIFIER::={ sonetObjects 2}sonetLine OBJECTIDENTIFIER::={ sonetObjects 3}sonetFarEndLine OBJECTIDENTIFIER::={ sonetObjects 4}sonetPath OBJECTIDENTIFIER::={ sonetObjectsPath 1}sonetFarEndPath OBJECTIDENTIFIER::={ sonetObjectsPath 2}sonetVT OBJECTIDENTIFIER::={ sonetObjectsVT 1}sonetFarEndVT OBJECTIDENTIFIER::={ sonetObjectsVT 2}-- the SONET/SDH Medium group
-- SONET/SDH interfaces for some applications may be electrical
-- interfaces and not optical interfaces. This group handles
-- the configuration information for both optical SONET/SDH
-- interfaces and electrical SONET/SDH interfaces.sonetMediumTable OBJECT-TYPESYNTAXSEQUENCEOF SonetMediumEntry
MAX-ACCESSnot-accessibleSTATUScurrentDESCRIPTION"The SONET/SDH Medium table."::={ sonetMedium 1}sonetMediumEntry OBJECT-TYPESYNTAX SonetMediumEntry
MAX-ACCESSnot-accessibleSTATUScurrentDESCRIPTION"An entry in the SONET/SDH Medium table."INDEX{ ifIndex }::={ sonetMediumTable 1}
SonetMediumEntry ::=SEQUENCE{
sonetMediumType INTEGER,
sonetMediumTimeElapsed Integer32,
sonetMediumValidIntervals Integer32,
sonetMediumLineCoding INTEGER,
sonetMediumLineType INTEGER,
sonetMediumCircuitIdentifier DisplayString,
sonetMediumInvalidIntervals Integer32,
sonetMediumLoopbackConfig BITS}sonetMediumType OBJECT-TYPESYNTAXINTEGER{sonet(1),sdh(2)}MAX-ACCESSread-writeSTATUScurrentDESCRIPTION"This variable identifies whether a SONET
or a SDH signal is used across this interface."::={ sonetMediumEntry 1}sonetMediumTimeElapsed OBJECT-TYPESYNTAXInteger32(1..900)MAX-ACCESSread-only
STATUScurrentDESCRIPTION"The number of seconds, including partial seconds,
that have elapsed since the beginning of the current
measurement period. If, for some reason, such as an
adjustment in the system's time-of-day clock, the
current interval exceeds the maximum value, the
agent will return the maximum value."::={ sonetMediumEntry 2}sonetMediumValidIntervals OBJECT-TYPESYNTAXInteger32(0..96)MAX-ACCESSread-onlySTATUScurrentDESCRIPTION"The number of previous 15-minute intervals
for which data was collected.
A SONET/SDH interface must be capable
of supporting at least n intervals.
The minimum value of n is 4.
The default of n is 32.
The maximum value of n is 96.
The value will be <n> unless the measurement was
(re-)started within the last (<n>*15) minutes, in which
case the value will be the number of complete 15
minute intervals for which the agent has at least
some data. In certain cases (e.g., in the case
where the agent is a proxy) it is possible that some
intervals are unavailable. In this case, this
interval is the maximum interval number for
which data is available. "::={ sonetMediumEntry 3}sonetMediumLineCoding OBJECT-TYPESYNTAXINTEGER{sonetMediumOther(1),sonetMediumB3ZS(2),sonetMediumCMI(3),sonetMediumNRZ(4),sonetMediumRZ(5)}MAX-ACCESSread-writeSTATUScurrentDESCRIPTION"This variable describes the line coding for
this interface. The B3ZS and CMI are used for
electrical SONET/SDH signals (STS-1 and STS-3).
The Non-Return to Zero (NRZ) and the Return
to Zero are used for optical SONET/SDH signals."::={ sonetMediumEntry 4}sonetMediumLineType OBJECT-TYPESYNTAXINTEGER{
sonetOther(1),sonetShortSingleMode(2),sonetLongSingleMode(3),sonetMultiMode(4),sonetCoax(5),sonetUTP(6)}MAX-ACCESSread-writeSTATUScurrentDESCRIPTION"This variable describes the line type for
this interface. The line types are
Short and Long Range
Single Mode fiber or Multi-Mode fiber interfaces,
and coax and UTP for electrical interfaces. The
value sonetOther should be used when the Line Type is
not one of the listed values."::={ sonetMediumEntry 5}sonetMediumCircuitIdentifier OBJECT-TYPESYNTAXDisplayString(SIZE(0..255))
MAX-ACCESSread-writeSTATUScurrentDESCRIPTION"This variable contains the transmission
vendor's circuit identifier, for the
purpose of facilitating troubleshooting.
Note that the circuit identifier, if available,
is also represented by ifPhysAddress."::={ sonetMediumEntry 6}sonetMediumInvalidIntervals OBJECT-TYPESYNTAXInteger32(0..96)MAX-ACCESSread-onlySTATUScurrentDESCRIPTION"The number of intervals in the range from
0 to sonetMediumValidIntervals for which no
data is available. This object will typically
be zero except in cases where the data for some
intervals are not available (e.g., in proxy
situations)."::={ sonetMediumEntry 7}sonetMediumLoopbackConfig OBJECT-TYPESYNTAXBITS{sonetNoLoop(0),
sonetFacilityLoop(1),sonetTerminalLoop(2),sonetOtherLoop(3)}MAX-ACCESSread-writeSTATUScurrentDESCRIPTION"The current loopback state of the SONET/SDH interface. The
values mean:
sonetNoLoop
Not in the loopback state. A device that is not
capable of performing a loopback on this interface
shall always return this value.
sonetFacilityLoop
The received signal at this interface is looped back
out through the corresponding transmitter in the return
direction.
sonetTerminalLoop
The signal that is about to be transmitted is connected
to the associated incoming receiver.
sonetOtherLoop
Loopbacks that are not defined here."::={ sonetMediumEntry 8}sonetSESthresholdSet OBJECT-TYPESYNTAXINTEGER{other(1),
Bellcore1991(2),ansi1993(3),itu1995(4),ansi1997(5)}MAX-ACCESSread-writeSTATUScurrentDESCRIPTION"An enumerated integer indicating which
recognized set of SES thresholds that
the agent uses for determining severely
errored seconds and unavailable time.
other(1)
None of the following.
Bellcore1991(2)
Bellcore TR-NWT-000253, 1991 [32], or
ANSI T1M1.3/93-005R2, 1993 [22].
See also Appendix B.
ansi1993(3)
ANSI T1.231, 1993 [31], or
Bellcore GR-253-CORE, Issue 2, 1995 [34]
itu1995(4)
ITU Recommendation G.826, 1995 [33]
ansi1997(5)
ANSI T1.231, 1997 [35]
If a manager changes the value of this
object then the SES statistics collected
prior to this change must be invalidated."::={ sonetMedium 2}-- the SONET/SDH Section group-- this group consists of 2 tables:
-- - the SONET/SDH Section Current Table
-- - the SONET/SDH Section Interval Table-- the SONET/SDH Section Current Table-- The SONET/SDH Section
-- current table contains various statistics
-- being collected for the current 15 minute interval.sonetSectionCurrentTable OBJECT-TYPESYNTAXSEQUENCEOF SonetSectionCurrentEntry
MAX-ACCESSnot-accessibleSTATUScurrentDESCRIPTION"The SONET/SDH Section Current table."::={ sonetSection 1}sonetSectionCurrentEntry OBJECT-TYPESYNTAX SonetSectionCurrentEntry
MAX-ACCESSnot-accessibleSTATUScurrentDESCRIPTION"An entry in the SONET/SDH Section Current table."INDEX{ ifIndex }::={ sonetSectionCurrentTable 1}
SonetSectionCurrentEntry ::=SEQUENCE{
sonetSectionCurrentStatus Integer32,
sonetSectionCurrentESs PerfCurrentCount,
sonetSectionCurrentSESs PerfCurrentCount,
sonetSectionCurrentSEFSs PerfCurrentCount,
sonetSectionCurrentCVs PerfCurrentCount}sonetSectionCurrentStatus OBJECT-TYPESYNTAXInteger32(1..6)MAX-ACCESSread-onlySTATUScurrentDESCRIPTION"This variable indicates the
status of the interface.
The sonetSectionCurrentStatus
is a bit map represented
as a sum, therefore,
it can represent multiple defects
simultaneously.
The sonetSectionNoDefect should be
set if and only if
no other flag is set.
The various bit positions are:
1 sonetSectionNoDefect
2 sonetSectionLOS
4 sonetSectionLOF"::={ sonetSectionCurrentEntry 1}sonetSectionCurrentESs OBJECT-TYPESYNTAXPerfCurrentCountMAX-ACCESSread-onlySTATUScurrent
DESCRIPTION"The counter associated with the number of Errored
Seconds encountered by a SONET/SDH
Section in the current 15 minute interval."::={ sonetSectionCurrentEntry 2}sonetSectionCurrentSESs OBJECT-TYPESYNTAXPerfCurrentCountMAX-ACCESSread-onlySTATUScurrentDESCRIPTION"The counter associated with the number of
Severely Errored Seconds
encountered by a SONET/SDH Section in the current 15
minute interval."::={ sonetSectionCurrentEntry 3}sonetSectionCurrentSEFSs OBJECT-TYPESYNTAXPerfCurrentCountMAX-ACCESSread-onlySTATUScurrentDESCRIPTION"The counter associated with the number of
Severely Errored Framing Seconds
encountered by a SONET/SDH Section in the current
15 minute interval."::={ sonetSectionCurrentEntry 4}sonetSectionCurrentCVs OBJECT-TYPESYNTAXPerfCurrentCountMAX-ACCESSread-onlySTATUScurrentDESCRIPTION"The counter associated with the number of Coding
Violations encountered by a
SONET/SDH Section in the current 15 minute interval."::={ sonetSectionCurrentEntry 5}-- the SONET/SDH Section Interval Table
-- The SONET/SDH Section Interval Table
-- contains various statistics
-- collected by each system over a maximum
-- of the previous 24 hours of
-- operation. The past 24 hours may be broken into 96
-- completed 15 minute intervals.
-- A system is required to store at
-- least 4 completed 15 minute interval.
-- The default value is 32 intervals.sonetSectionIntervalTable OBJECT-TYPESYNTAXSEQUENCEOF SonetSectionIntervalEntry
MAX-ACCESSnot-accessibleSTATUScurrentDESCRIPTION"The SONET/SDH Section Interval table."::={ sonetSection 2}sonetSectionIntervalEntry OBJECT-TYPESYNTAX SonetSectionIntervalEntry
MAX-ACCESSnot-accessibleSTATUScurrentDESCRIPTION"An entry in the SONET/SDH Section Interval table."INDEX{ ifIndex,
sonetSectionIntervalNumber }::={ sonetSectionIntervalTable 1}
SonetSectionIntervalEntry ::=SEQUENCE{
sonetSectionIntervalNumber Integer32,
sonetSectionIntervalESs PerfIntervalCount,
sonetSectionIntervalSESs PerfIntervalCount,
sonetSectionIntervalSEFSs PerfIntervalCount,
sonetSectionIntervalCVs PerfIntervalCount,
sonetSectionIntervalValidData TruthValue}sonetSectionIntervalNumber OBJECT-TYPESYNTAXInteger32(1..96)MAX-ACCESSnot-accessibleSTATUScurrent
DESCRIPTION"A number between 1 and 96, which identifies the
interval for which the set of statistics is available.
The interval identified by 1 is the most recently
completed 15 minute interval,
and the interval identified
by N is the interval immediately preceding the
one identified
by N-1."::={ sonetSectionIntervalEntry 1}sonetSectionIntervalESs OBJECT-TYPESYNTAXPerfIntervalCountMAX-ACCESSread-onlySTATUScurrentDESCRIPTION"The counter associated with the number of
Errored Seconds encountered
by a SONET/SDH Section in a
particular 15-minute interval
in the past 24 hours."::={ sonetSectionIntervalEntry 2}sonetSectionIntervalSESs OBJECT-TYPESYNTAXPerfIntervalCountMAX-ACCESSread-onlySTATUScurrentDESCRIPTION"The counter associated with the number of
Severely Errored Seconds
encountered by a SONET/SDH Section in a
particular 15-minute interval
in the past 24 hours."::={ sonetSectionIntervalEntry 3}sonetSectionIntervalSEFSs OBJECT-TYPESYNTAXPerfIntervalCountMAX-ACCESSread-onlySTATUScurrentDESCRIPTION"The counter associated with the number of
Severely Errored Framing Seconds
encountered by a SONET/SDH Section in a
particular 15-minute interval
in the past 24 hours."::={ sonetSectionIntervalEntry 4}sonetSectionIntervalCVs OBJECT-TYPESYNTAXPerfIntervalCountMAX-ACCESSread-onlySTATUScurrentDESCRIPTION"The counter associated with the number of Coding
Violations encountered by a
SONET/SDH Section in a particular 15-minute interval
in the past 24 hours."::={ sonetSectionIntervalEntry 5}sonetSectionIntervalValidData OBJECT-TYPESYNTAXTruthValueMAX-ACCESSread-only
STATUScurrentDESCRIPTION"This variable indicates if the data for this
interval is valid."::={ sonetSectionIntervalEntry 6}-- the SONET/SDH Line group-- this group consists of 2 tables:
-- - the SONET/SDH Line Current Table
-- - the SONET/SDH Line Interval Table-- the SONET/SDH Line Current Table-- The SONET/SDH Line
-- current table contains various statistics
-- being collected for the current 15 minute interval.sonetLineCurrentTable OBJECT-TYPESYNTAXSEQUENCEOF SonetLineCurrentEntry
MAX-ACCESSnot-accessibleSTATUScurrentDESCRIPTION"The SONET/SDH Line Current table."::={ sonetLine 1}sonetLineCurrentEntry OBJECT-TYPESYNTAX SonetLineCurrentEntry
MAX-ACCESSnot-accessibleSTATUScurrentDESCRIPTION"An entry in the SONET/SDH Line Current table."INDEX{ ifIndex }
::={ sonetLineCurrentTable 1}
SonetLineCurrentEntry ::=SEQUENCE{
sonetLineCurrentStatus Integer32,
sonetLineCurrentESs PerfCurrentCount,
sonetLineCurrentSESs PerfCurrentCount,
sonetLineCurrentCVs PerfCurrentCount,
sonetLineCurrentUASs PerfCurrentCount}sonetLineCurrentStatus OBJECT-TYPESYNTAXInteger32(1..6)MAX-ACCESSread-onlySTATUScurrentDESCRIPTION"This variable indicates the
status of the interface.
The sonetLineCurrentStatus
is a bit map represented
as a sum, therefore,
it can represent multiple defects
simultaneously.
The sonetLineNoDefect should be
set if and only if
no other flag is set.
The various bit positions are:
1 sonetLineNoDefect
2 sonetLineAIS
4 sonetLineRDI"
::={ sonetLineCurrentEntry 1}sonetLineCurrentESs OBJECT-TYPESYNTAXPerfCurrentCountMAX-ACCESSread-onlySTATUScurrentDESCRIPTION"The counter associated with the number of Errored
Seconds encountered by a SONET/SDH
Line in the current 15 minute interval."::={ sonetLineCurrentEntry 2}sonetLineCurrentSESs OBJECT-TYPESYNTAXPerfCurrentCountMAX-ACCESSread-onlySTATUScurrentDESCRIPTION"The counter associated with the number of
Severely Errored Seconds
encountered by a SONET/SDH Line in the current 15
minute
interval."::={ sonetLineCurrentEntry 3}sonetLineCurrentCVs OBJECT-TYPESYNTAXPerfCurrentCountMAX-ACCESSread-onlySTATUScurrentDESCRIPTION
"The counter associated with the number of Coding
Violations encountered by a
SONET/SDH Line in the current 15 minute interval."::={ sonetLineCurrentEntry 4}sonetLineCurrentUASs OBJECT-TYPESYNTAXPerfCurrentCountMAX-ACCESSread-onlySTATUScurrentDESCRIPTION"The counter associated with the number of
Unavailable Seconds
encountered by a SONET/SDH Line in the current 15
minute
interval."::={ sonetLineCurrentEntry 5}-- the SONET/SDH Line Interval Table-- The SONET/SDH Line Interval Table
-- contains various statistics
-- collected by each system over a maximum
-- of the previous 24 hours of
-- operation. The past 24 hours may be broken into 96
-- completed 15 minute intervals.
-- A system is required to store at
-- least 4 completed 15 minute interval.
-- The default value is 32 intervals.sonetLineIntervalTable OBJECT-TYPESYNTAXSEQUENCEOF SonetLineIntervalEntry
MAX-ACCESSnot-accessibleSTATUScurrentDESCRIPTION
"The SONET/SDH Line Interval table."::={ sonetLine 2}sonetLineIntervalEntry OBJECT-TYPESYNTAX SonetLineIntervalEntry
MAX-ACCESSnot-accessibleSTATUScurrentDESCRIPTION"An entry in the SONET/SDH Line Interval table."INDEX{ ifIndex,
sonetLineIntervalNumber }::={ sonetLineIntervalTable 1}
SonetLineIntervalEntry ::=SEQUENCE{
sonetLineIntervalNumber Integer32,
sonetLineIntervalESs PerfIntervalCount,
sonetLineIntervalSESs PerfIntervalCount,
sonetLineIntervalCVs PerfIntervalCount,
sonetLineIntervalUASs PerfIntervalCount,
sonetLineIntervalValidData TruthValue}sonetLineIntervalNumber OBJECT-TYPESYNTAXInteger32(1..96)
MAX-ACCESSnot-accessibleSTATUScurrentDESCRIPTION"A number between 1 and 96, which identifies the
interval for which the set of statistics is available.
The interval identified by 1 is the most recently
completed 15 minute interval,
and the interval identified
by N is the interval immediately preceding the
one identified
by N-1."::={ sonetLineIntervalEntry 1}sonetLineIntervalESs OBJECT-TYPESYNTAXPerfIntervalCountMAX-ACCESSread-onlySTATUScurrentDESCRIPTION"The counter associated with the number of
Errored Seconds encountered
by a SONET/SDH Line in a
particular 15-minute interval
in the past 24 hours."::={ sonetLineIntervalEntry 2}sonetLineIntervalSESs OBJECT-TYPESYNTAXPerfIntervalCountMAX-ACCESSread-onlySTATUScurrent
DESCRIPTION"The counter associated with the number of
Severely Errored Seconds
encountered by a SONET/SDH Line in a
particular 15-minute interval
in the past 24 hours."::={ sonetLineIntervalEntry 3}sonetLineIntervalCVs OBJECT-TYPESYNTAXPerfIntervalCountMAX-ACCESSread-onlySTATUScurrentDESCRIPTION"The counter associated with the number of Coding
Violations encountered by a
SONET/SDH Line in a
particular 15-minute interval
in the past 24 hours."::={ sonetLineIntervalEntry 4}sonetLineIntervalUASs OBJECT-TYPESYNTAXPerfIntervalCountMAX-ACCESSread-onlySTATUScurrentDESCRIPTION"The counter associated with the
number of Unavailable Seconds
encountered by a SONET/SDH Line in
a particular 15-minute interval
in the past 24 hours."::={ sonetLineIntervalEntry 5}
sonetLineIntervalValidData OBJECT-TYPESYNTAXTruthValueMAX-ACCESSread-onlySTATUScurrentDESCRIPTION"This variable indicates if the data for this
interval is valid."::={ sonetLineIntervalEntry 6}-- The SONET/SDH Far End Line group.
-- This group may only be implemented by SONET/SDH (LTEs)
-- systems that provide for a far end block error (FEBE)
-- information at the SONET/SDH Line Layer.-- This group consists of two tables:
-- SONET/SDH Far End Line Current Table
-- SONET/SDH Far End Line Interval Table-- The SONET/SDH Far End Line Current Table-- The SONET/SDH Far End Line Current table contains
-- various statistics being
-- collected for the current 15 minute interval.
-- The statistics are collected from the far end
-- block error code (FEBE)
-- within the third Z2 byte of the Line Overhead
-- in Broadband ISDN applications.
-- The definitions are the same as described for
-- the near-end information.sonetFarEndLineCurrentTable OBJECT-TYPESYNTAXSEQUENCEOF SonetFarEndLineCurrentEntry
MAX-ACCESSnot-accessible
STATUScurrentDESCRIPTION"The SONET/SDH Far End Line Current table."::={ sonetFarEndLine 1}sonetFarEndLineCurrentEntry OBJECT-TYPESYNTAX SonetFarEndLineCurrentEntry
MAX-ACCESSnot-accessibleSTATUScurrentDESCRIPTION"An entry in the SONET/SDH Far End Line Current table."INDEX{ ifIndex }::={ sonetFarEndLineCurrentTable 1}
SonetFarEndLineCurrentEntry ::=SEQUENCE{
sonetFarEndLineCurrentESs PerfCurrentCount,
sonetFarEndLineCurrentSESs PerfCurrentCount,
sonetFarEndLineCurrentCVs PerfCurrentCount,
sonetFarEndLineCurrentUASs PerfCurrentCount}sonetFarEndLineCurrentESs OBJECT-TYPESYNTAXPerfCurrentCountMAX-ACCESSread-onlySTATUScurrent
DESCRIPTION"The counter associated with the number of Far
End Errored Seconds encountered by a SONET/SDH
interface in the current 15 minute interval."::={ sonetFarEndLineCurrentEntry 1}sonetFarEndLineCurrentSESs OBJECT-TYPESYNTAXPerfCurrentCountMAX-ACCESSread-onlySTATUScurrentDESCRIPTION"The counter associated with the number of
Far End Severely Errored Seconds
encountered by a SONET/SDH Medium/Section/Line
interface in the current 15 minute
interval."::={ sonetFarEndLineCurrentEntry 2}sonetFarEndLineCurrentCVs OBJECT-TYPESYNTAXPerfCurrentCountMAX-ACCESSread-onlySTATUScurrentDESCRIPTION"The counter associated with the number of
Far End Coding Violations reported via
the far end block error count
encountered by a
SONET/SDH Medium/Section/Line
interface in the current 15 minute interval."::={ sonetFarEndLineCurrentEntry 3}
sonetFarEndLineCurrentUASs OBJECT-TYPESYNTAXPerfCurrentCountMAX-ACCESSread-onlySTATUScurrentDESCRIPTION"The counter associated with the number of
Far End Unavailable Seconds
encountered by a
SONET/SDH Medium/Section/Line
interface in the current 15 minute interval."::={ sonetFarEndLineCurrentEntry 4}-- The SONET/SDH Far End Line Interval Table-- The SONET/SDH Far End Line Interval Table
-- contains various statistics
-- collected by each system over a maximum
-- of the previous 24 hours of
-- operation. The past 24 hours may be broken into 96
-- completed 15 minute intervals.
-- A system is required to store at
-- least 4 completed 15 minute interval.
-- The default value is 32 intervals.sonetFarEndLineIntervalTable OBJECT-TYPESYNTAXSEQUENCEOF SonetFarEndLineIntervalEntry
MAX-ACCESSnot-accessibleSTATUScurrentDESCRIPTION"The SONET/SDH Far End Line Interval table."::={ sonetFarEndLine 2}
sonetFarEndLineIntervalEntry OBJECT-TYPESYNTAX SonetFarEndLineIntervalEntry
MAX-ACCESSnot-accessibleSTATUScurrentDESCRIPTION"An entry in the SONET/SDH Far
End Line Interval table."INDEX{ ifIndex,
sonetFarEndLineIntervalNumber }::={ sonetFarEndLineIntervalTable 1}
SonetFarEndLineIntervalEntry ::=SEQUENCE{
sonetFarEndLineIntervalNumber Integer32,
sonetFarEndLineIntervalESs PerfIntervalCount,
sonetFarEndLineIntervalSESs PerfIntervalCount,
sonetFarEndLineIntervalCVs PerfIntervalCount,
sonetFarEndLineIntervalUASs PerfIntervalCount,
sonetFarEndLineIntervalValidData TruthValue}sonetFarEndLineIntervalNumber OBJECT-TYPESYNTAXInteger32(1..96)
MAX-ACCESSnot-accessibleSTATUScurrentDESCRIPTION"A number between 1 and 96, which identifies the
interval for which the set of statistics is available.
The interval identified by 1 is the most recently
completed 15 minute interval,
and the interval identified
by N is the interval immediately preceding the
one identified
by N-1."::={ sonetFarEndLineIntervalEntry 1}sonetFarEndLineIntervalESs OBJECT-TYPESYNTAXPerfIntervalCountMAX-ACCESSread-onlySTATUScurrentDESCRIPTION"The counter associated with the number of
Far End Errored Seconds encountered
by a SONET/SDH Line
interface in a particular 15-minute interval
in the past 24 hours."::={ sonetFarEndLineIntervalEntry 2}sonetFarEndLineIntervalSESs OBJECT-TYPESYNTAXPerfIntervalCountMAX-ACCESSread-only
STATUScurrentDESCRIPTION"The counter associated with the number of
Far End Severely Errored Seconds
encountered by a SONET/SDH Line
interface in a particular 15-minute interval
in the past 24 hours."::={ sonetFarEndLineIntervalEntry 3}sonetFarEndLineIntervalCVs OBJECT-TYPESYNTAXPerfIntervalCountMAX-ACCESSread-onlySTATUScurrentDESCRIPTION"The counter associated with the number of
Far End Coding Violations reported via
the far end block error count
encountered by a
SONET/SDH Line
interface in a particular 15-minute interval
in the past 24 hours."::={ sonetFarEndLineIntervalEntry 4}sonetFarEndLineIntervalUASs OBJECT-TYPESYNTAXPerfIntervalCountMAX-ACCESSread-onlySTATUScurrentDESCRIPTION"The counter associated with the number of
Far End Unavailable Seconds
encountered by a
SONET/SDH Line
interface in a particular 15-minute interval
in the past 24 hours."::={ sonetFarEndLineIntervalEntry 5}sonetFarEndLineIntervalValidData OBJECT-TYPESYNTAXTruthValueMAX-ACCESSread-onlySTATUScurrentDESCRIPTION"This variable indicates if the data for this
interval is valid."::={ sonetFarEndLineIntervalEntry 6}-- the SONET/SDH Path group-- this group consists of 2 tables:
-- - the SONET/SDH Path Current Table
-- - the SONET/SDH Path Interval Table-- the SONET/SDH Path Current Table-- The SONET/SDH Path
-- current table contains various statistics
-- being collected for the current 15 minute interval.sonetPathCurrentTable OBJECT-TYPESYNTAXSEQUENCEOF SonetPathCurrentEntry
MAX-ACCESSnot-accessibleSTATUScurrentDESCRIPTION"The SONET/SDH Path Current table."::={ sonetPath 1}
sonetPathCurrentEntry OBJECT-TYPESYNTAX SonetPathCurrentEntry
MAX-ACCESSnot-accessibleSTATUScurrentDESCRIPTION"An entry in the SONET/SDH Path Current table."INDEX{ ifIndex }
::={ sonetPathCurrentTable 1}
SonetPathCurrentEntry ::=SEQUENCE{
sonetPathCurrentWidth INTEGER,
sonetPathCurrentStatus Integer32,
sonetPathCurrentESs PerfCurrentCount,
sonetPathCurrentSESs PerfCurrentCount,
sonetPathCurrentCVs PerfCurrentCount,
sonetPathCurrentUASs PerfCurrentCount}sonetPathCurrentWidth OBJECT-TYPESYNTAXINTEGER{sts1(1),sts3cSTM1(2),
sts12cSTM4(3),sts24c(4),sts48cSTM16(5)}MAX-ACCESSread-writeSTATUScurrentDESCRIPTION"A value that indicates the type of the SONET/SDH
Path. For SONET, the assigned types are
the STS-Nc SPEs, where N = 1, 3, 12, 24, and 48.
STS-1 is equal to 51.84 Mbps. For SDH, the assigned
types are the STM-Nc VCs, where N = 1, 4, and 16."::={ sonetPathCurrentEntry 1}sonetPathCurrentStatus OBJECT-TYPESYNTAXInteger32(1..62)MAX-ACCESSread-onlySTATUScurrentDESCRIPTION"This variable indicates the
status of the interface.
The sonetPathCurrentStatus
is a bit map represented
as a sum, therefore,
it can represent multiple defects
simultaneously.
The sonetPathNoDefect should be
set if and only if
no other flag is set.
The various bit positions are:
1 sonetPathNoDefect
2 sonetPathSTSLOP
4 sonetPathSTSAIS
8 sonetPathSTSRDI
16 sonetPathUnequipped
32 sonetPathSignalLabelMismatch"::={ sonetPathCurrentEntry 2}sonetPathCurrentESs OBJECT-TYPESYNTAXPerfCurrentCountMAX-ACCESSread-onlySTATUScurrentDESCRIPTION"The counter associated with the number of Errored
Seconds encountered by a SONET/SDH
Path in the current 15 minute interval."::={ sonetPathCurrentEntry 3}sonetPathCurrentSESs OBJECT-TYPESYNTAXPerfCurrentCountMAX-ACCESSread-onlySTATUScurrentDESCRIPTION"The counter associated with the number of
Severely Errored Seconds
encountered by a SONET/SDH Path in the current 15
minute
interval."::={ sonetPathCurrentEntry 4}sonetPathCurrentCVs OBJECT-TYPE
SYNTAXPerfCurrentCountMAX-ACCESSread-onlySTATUScurrentDESCRIPTION"The counter associated with the number of Coding
Violations encountered by a
SONET/SDH Path in the current 15 minute interval."::={ sonetPathCurrentEntry 5}sonetPathCurrentUASs OBJECT-TYPESYNTAXPerfCurrentCountMAX-ACCESSread-onlySTATUScurrentDESCRIPTION"The counter associated with the number of
Unavailable Seconds
encountered by a Path in the current
15 minute interval."::={ sonetPathCurrentEntry 6}-- the SONET/SDH Path Interval Table-- The SONET/SDH Path Interval Table
-- contains various statistics
-- collected by each system over a maximum
-- of the previous 24 hours of
-- operation. The past 24 hours may be broken into 96
-- completed 15 minute intervals.
-- A system is required to store at
-- least 4 completed 15 minute interval.
-- The default value is 32 intervals.sonetPathIntervalTable OBJECT-TYPESYNTAXSEQUENCEOF SonetPathIntervalEntry
MAX-ACCESSnot-accessibleSTATUScurrentDESCRIPTION"The SONET/SDH Path Interval table."::={ sonetPath 2}sonetPathIntervalEntry OBJECT-TYPESYNTAX SonetPathIntervalEntry
MAX-ACCESSnot-accessibleSTATUScurrentDESCRIPTION"An entry in the SONET/SDH Path Interval table."INDEX{ ifIndex,
sonetPathIntervalNumber }
::={ sonetPathIntervalTable 1}
SonetPathIntervalEntry ::=SEQUENCE{
sonetPathIntervalNumber Integer32,
sonetPathIntervalESs PerfIntervalCount,
sonetPathIntervalSESs PerfIntervalCount,
sonetPathIntervalCVs PerfIntervalCount,
sonetPathIntervalUASs PerfIntervalCount,
sonetPathIntervalValidData TruthValue
}sonetPathIntervalNumber OBJECT-TYPESYNTAXInteger32(1..96)MAX-ACCESSnot-accessibleSTATUScurrentDESCRIPTION"A number between 1 and 96, which identifies the
interval for which the set of statistics is available.
The interval identified by 1 is the most recently
completed 15 minute interval,
and the interval identified
by N is the interval immediately preceding the
one identified
by N-1."::={ sonetPathIntervalEntry 1}sonetPathIntervalESs OBJECT-TYPESYNTAXPerfIntervalCountMAX-ACCESSread-onlySTATUScurrentDESCRIPTION"The counter associated with the number of
Errored Seconds encountered
by a SONET/SDH Path in a
particular 15-minute interval
in the past 24 hours."::={ sonetPathIntervalEntry 2}sonetPathIntervalSESs OBJECT-TYPE
SYNTAXPerfIntervalCountMAX-ACCESSread-onlySTATUScurrentDESCRIPTION"The counter associated with the number of
Severely Errored Seconds
encountered by a SONET/SDH Path in
a particular 15-minute interval
in the past 24 hours."::={ sonetPathIntervalEntry 3}sonetPathIntervalCVs OBJECT-TYPESYNTAXPerfIntervalCountMAX-ACCESSread-onlySTATUScurrentDESCRIPTION"The counter associated with the number of Coding
Violations encountered by a
SONET/SDH Path in a particular 15-minute interval
in the past 24 hours."::={ sonetPathIntervalEntry 4}sonetPathIntervalUASs OBJECT-TYPESYNTAXPerfIntervalCountMAX-ACCESSread-onlySTATUScurrentDESCRIPTION"The counter associated with the number of
Unavailable Seconds
encountered by a Path in a
particular 15-minute interval
in the past 24 hours."::={ sonetPathIntervalEntry 5}sonetPathIntervalValidData OBJECT-TYPESYNTAXTruthValueMAX-ACCESSread-onlySTATUScurrentDESCRIPTION"This variable indicates if the data for this
interval is valid."::={ sonetPathIntervalEntry 6}-- The SONET/SDH Far End Path group-- This group consists of two tables:
-- - SONET/SDH Far End Path Current Table
-- - SONET/SDH Far End Path Interval Table-- The SONET/SDH Far End Path Current Table-- The SONET/SDH Far End Path Current table
-- contains various statistics
-- being collected for the current 15 minute interval.
-- The statistics are collected from
-- the far end block error code
-- (FEBE) within the G1 byte of the Path Overhead.
-- The definitions are the same as described for
-- the near-end information.sonetFarEndPathCurrentTable OBJECT-TYPESYNTAXSEQUENCEOF SonetFarEndPathCurrentEntry
MAX-ACCESSnot-accessibleSTATUScurrent
DESCRIPTION"The SONET/SDH Far End Path Current table."::={ sonetFarEndPath 1}sonetFarEndPathCurrentEntry OBJECT-TYPESYNTAX SonetFarEndPathCurrentEntry
MAX-ACCESSnot-accessibleSTATUScurrentDESCRIPTION"An entry in the SONET/SDH Far End Path Current table."INDEX{ ifIndex }::={ sonetFarEndPathCurrentTable 1}
SonetFarEndPathCurrentEntry ::=SEQUENCE{
sonetFarEndPathCurrentESs PerfCurrentCount,
sonetFarEndPathCurrentSESs PerfCurrentCount,
sonetFarEndPathCurrentCVs PerfCurrentCount,
sonetFarEndPathCurrentUASs PerfCurrentCount}sonetFarEndPathCurrentESs OBJECT-TYPESYNTAXPerfCurrentCountMAX-ACCESSread-onlySTATUScurrent
DESCRIPTION"The counter associated with the number of Far
End Errored Seconds encountered by a SONET/SDH
interface in the current 15 minute interval."::={ sonetFarEndPathCurrentEntry 1}sonetFarEndPathCurrentSESs OBJECT-TYPESYNTAXPerfCurrentCountMAX-ACCESSread-onlySTATUScurrentDESCRIPTION"The counter associated with the number of
Far End Severely Errored Seconds
encountered by a SONET/SDH Path
interface in the current 15 minute
interval."::={ sonetFarEndPathCurrentEntry 2}sonetFarEndPathCurrentCVs OBJECT-TYPESYNTAXPerfCurrentCountMAX-ACCESSread-onlySTATUScurrentDESCRIPTION"The counter associated with the number of
Far End Coding Violations reported via
the far end block error count
encountered by a
SONET/SDH Path interface in
the current 15 minute interval."::={ sonetFarEndPathCurrentEntry 3}
sonetFarEndPathCurrentUASs OBJECT-TYPESYNTAXPerfCurrentCountMAX-ACCESSread-onlySTATUScurrentDESCRIPTION"The counter associated with the number of
Far End Unavailable Seconds
encountered by a
SONET/SDH Path interface in
the current 15 minute interval."::={ sonetFarEndPathCurrentEntry 4}-- The SONET/SDH Far End Path Interval Table-- The SONET/SDH Far End Path Interval Table
-- contains various statistics
-- collected by each system over a maximum
-- of the previous 24 hours of
-- operation. The past 24 hours may be broken into 96
-- completed 15 minute intervals.
-- A system is required to store at
-- least 4 completed 15 minute interval.
-- The default value is 32 intervals.sonetFarEndPathIntervalTable OBJECT-TYPESYNTAXSEQUENCEOF SonetFarEndPathIntervalEntry
MAX-ACCESSnot-accessibleSTATUScurrentDESCRIPTION"The SONET/SDH Far End Path Interval table."::={ sonetFarEndPath 2}
sonetFarEndPathIntervalEntry OBJECT-TYPESYNTAX SonetFarEndPathIntervalEntry
MAX-ACCESSnot-accessibleSTATUScurrentDESCRIPTION"An entry in the SONET/SDH Far
End Path Interval table."INDEX{ ifIndex,
sonetFarEndPathIntervalNumber }::={ sonetFarEndPathIntervalTable 1}
SonetFarEndPathIntervalEntry ::=SEQUENCE{
sonetFarEndPathIntervalNumber Integer32,
sonetFarEndPathIntervalESs PerfIntervalCount,
sonetFarEndPathIntervalSESs PerfIntervalCount,
sonetFarEndPathIntervalCVs PerfIntervalCount,
sonetFarEndPathIntervalUASs PerfIntervalCount,
sonetFarEndPathIntervalValidData TruthValue}sonetFarEndPathIntervalNumber OBJECT-TYPESYNTAXInteger32(1..96)
MAX-ACCESSnot-accessibleSTATUScurrentDESCRIPTION"A number between 1 and 96, which identifies the
interval for which the set of statistics is available.
The interval identified by 1 is the most recently
completed 15 minute interval,
and the interval identified
by N is the interval immediately preceding the
one identified
by N-1."::={ sonetFarEndPathIntervalEntry 1}sonetFarEndPathIntervalESs OBJECT-TYPESYNTAXPerfIntervalCountMAX-ACCESSread-onlySTATUScurrentDESCRIPTION"The counter associated with the number of
Far End Errored Seconds encountered
by a SONET/SDH Path interface in a
particular 15-minute interval
in the past 24 hours."::={ sonetFarEndPathIntervalEntry 2}sonetFarEndPathIntervalSESs OBJECT-TYPESYNTAXPerfIntervalCountMAX-ACCESSread-only
STATUScurrentDESCRIPTION"The counter associated with the number of
Far End Severely Errored Seconds
encountered by a SONET/SDH Path interface
in a particular 15-minute interval
in the past 24 hours."::={ sonetFarEndPathIntervalEntry 3}sonetFarEndPathIntervalCVs OBJECT-TYPESYNTAXPerfIntervalCountMAX-ACCESSread-onlySTATUScurrentDESCRIPTION"The counter associated with the number of
Far End Coding Violations reported via
the far end block error count
encountered by a
SONET/SDH Path interface
in a particular 15-minute interval
in the past 24 hours."::={ sonetFarEndPathIntervalEntry 4}sonetFarEndPathIntervalUASs OBJECT-TYPESYNTAXPerfIntervalCountMAX-ACCESSread-onlySTATUScurrentDESCRIPTION"The counter associated with the number of
Far End Unavailable Seconds
encountered by a
SONET/SDH Path interface in
a particular 15-minute interval
in the past 24 hours."::={ sonetFarEndPathIntervalEntry 5}sonetFarEndPathIntervalValidData OBJECT-TYPESYNTAXTruthValueMAX-ACCESSread-onlySTATUScurrentDESCRIPTION"This variable indicates if the data for this
interval is valid."::={ sonetFarEndPathIntervalEntry 6}-- the SONET/SDH Virtual Tributary group-- this group consists of 2 tables:
-- - the SONET/SDH VT Current Table
-- - the SONET/SDH VT Interval Table-- For SDH signals, virtual tributaries are
-- called VCs instead of VTs-- A VT1.5 = VC11
-- A VT2 = VC12
-- A VT3 = none
-- A VT6 = VC3-- the SONET/SDH VT Current Table-- The SONET/SDH VT current table
-- contains various statistics
-- being collected for the
-- current 15 minute interval.sonetVTCurrentTable OBJECT-TYPESYNTAXSEQUENCEOF SonetVTCurrentEntry
MAX-ACCESSnot-accessible
STATUScurrentDESCRIPTION"The SONET/SDH VT Current table."::={ sonetVT 1}sonetVTCurrentEntry OBJECT-TYPESYNTAX SonetVTCurrentEntry
MAX-ACCESSnot-accessibleSTATUScurrentDESCRIPTION"An entry in the SONET/SDH VT Current table."INDEX{ ifIndex }
::={ sonetVTCurrentTable 1}
SonetVTCurrentEntry ::=SEQUENCE{
sonetVTCurrentWidth INTEGER,
sonetVTCurrentStatus Integer32,
sonetVTCurrentESs PerfCurrentCount,
sonetVTCurrentSESs PerfCurrentCount,
sonetVTCurrentCVs PerfCurrentCount,
sonetVTCurrentUASs PerfCurrentCount}sonetVTCurrentWidth OBJECT-TYPESYNTAXINTEGER{
vtWidth15VC11(1),vtWidth2VC12(2),vtWidth3(3),vtWidth6VC2(4),vtWidth6c(5)}MAX-ACCESSread-writeSTATUScurrentDESCRIPTION"A value that indicates the type of the SONET
VT and SDH VC. Assigned widths are
VT1.5/VC11, VT2/VC12, VT3, VT6/VC2, and VT6c."::={ sonetVTCurrentEntry 1}sonetVTCurrentStatus OBJECT-TYPESYNTAXInteger32(1..126)MAX-ACCESSread-onlySTATUScurrentDESCRIPTION"This variable indicates the
status of the interface.
The sonetVTCurrentStatus
is a bit map represented
as a sum, therefore,
it can represent multiple defects
and failures
simultaneously.
The sonetVTNoDefect should be
set if and only if
no other flag is set.
The various bit positions are:
1 sonetVTNoDefect
2 sonetVTLOP
4 sonetVTPathAIS
8 sonetVTPathRDI
16 sonetVTPathRFI
32 sonetVTUnequipped
64 sonetVTSignalLabelMismatch"::={ sonetVTCurrentEntry 2}sonetVTCurrentESs OBJECT-TYPESYNTAXPerfCurrentCountMAX-ACCESSread-onlySTATUScurrentDESCRIPTION"The counter associated with the number of Errored
Seconds encountered by a SONET/SDH
VT in the current 15 minute interval."::={ sonetVTCurrentEntry 3}sonetVTCurrentSESs OBJECT-TYPESYNTAXPerfCurrentCountMAX-ACCESSread-onlySTATUScurrentDESCRIPTION"The counter associated with the number of
Severely Errored Seconds
encountered by a SONET/SDH VT in the current 15 minute
interval."::={ sonetVTCurrentEntry 4}
sonetVTCurrentCVs OBJECT-TYPESYNTAXPerfCurrentCountMAX-ACCESSread-onlySTATUScurrentDESCRIPTION"The counter associated with the number of Coding
Violations encountered by a
SONET/SDH VT in the current 15 minute interval."::={ sonetVTCurrentEntry 5}sonetVTCurrentUASs OBJECT-TYPESYNTAXPerfCurrentCountMAX-ACCESSread-onlySTATUScurrentDESCRIPTION"The counter associated with the number of
Unavailable Seconds
encountered by a VT in the current
15 minute interval."::={ sonetVTCurrentEntry 6}-- the SONET/SDH VT Interval Table-- The SONET/SDH VT Interval Table
-- contains various statistics
-- collected by each system over a maximum
-- of the previous 24 hours of
-- operation. The past 24 hours may be broken into 96
-- completed 15 minute intervals.
-- A system is required to store at
-- least 4 completed 15 minute interval.
-- The default value is 32 intervals.sonetVTIntervalTable OBJECT-TYPESYNTAXSEQUENCEOF SonetVTIntervalEntry
MAX-ACCESSnot-accessibleSTATUScurrentDESCRIPTION"The SONET/SDH VT Interval table."::={ sonetVT 2}sonetVTIntervalEntry OBJECT-TYPESYNTAX SonetVTIntervalEntry
MAX-ACCESSnot-accessibleSTATUScurrentDESCRIPTION"An entry in the SONET/SDH VT Interval table."INDEX{ ifIndex,
sonetVTIntervalNumber }
::={ sonetVTIntervalTable 1}
SonetVTIntervalEntry ::=SEQUENCE{
sonetVTIntervalNumber Integer32,
sonetVTIntervalESs PerfIntervalCount,
sonetVTIntervalSESs PerfIntervalCount,
sonetVTIntervalCVs PerfIntervalCount,
sonetVTIntervalUASs PerfIntervalCount,
sonetVTIntervalValidData TruthValue}sonetVTIntervalNumber OBJECT-TYPESYNTAXInteger32(1..96)MAX-ACCESSnot-accessibleSTATUScurrentDESCRIPTION"A number between 1 and 96, which identifies the
interval for which the set of statistics is available.
The interval identified by 1 is the most recently
completed 15 minute interval,
and the interval identified
by N is the interval immediately preceding the
one identified
by N-1."::={ sonetVTIntervalEntry 1}sonetVTIntervalESs OBJECT-TYPESYNTAXPerfIntervalCountMAX-ACCESSread-onlySTATUScurrentDESCRIPTION"The counter associated with the number of
Errored Seconds encountered
by a SONET/SDH VT in a particular 15-minute interval
in the past 24 hours."::={ sonetVTIntervalEntry 2}
sonetVTIntervalSESs OBJECT-TYPESYNTAXPerfIntervalCountMAX-ACCESSread-onlySTATUScurrentDESCRIPTION"The counter associated with the number of
Severely Errored Seconds
encountered by a SONET/SDH VT
in a particular 15-minute interval
in the past 24 hours."::={ sonetVTIntervalEntry 3}sonetVTIntervalCVs OBJECT-TYPESYNTAXPerfIntervalCountMAX-ACCESSread-onlySTATUScurrentDESCRIPTION"The counter associated with the number of Coding
Violations encountered by a
SONET/SDH VT in a particular 15-minute interval
in the past 24 hours."::={ sonetVTIntervalEntry 4}sonetVTIntervalUASs OBJECT-TYPESYNTAXPerfIntervalCountMAX-ACCESSread-onlySTATUScurrentDESCRIPTION"The counter associated with the number of
Unavailable Seconds
encountered by a VT in a particular 15-minute interval
in the past 24 hours."::={ sonetVTIntervalEntry 5}sonetVTIntervalValidData OBJECT-TYPESYNTAXTruthValueMAX-ACCESSread-onlySTATUScurrentDESCRIPTION"This variable indicates if the data for this
interval is valid."::={ sonetVTIntervalEntry 6}-- The SONET/SDH Far End VT group-- This group consists of two tables:
-- SONET/SDH Far End VT Current Table
-- SONET/SDH Far End VT Interval Table-- The SONET/SDH Far End VT Current-- The SONET/SDH Far End VT Current table
-- contains various statistics
-- being collected for the current 15 minute interval.
-- The statistics are collected from
-- the far end block error code
-- (FEBE) within the G1 byte of the VT Overhead.
-- The definitions are the same as described for
-- the near-end information.sonetFarEndVTCurrentTable OBJECT-TYPESYNTAXSEQUENCEOF SonetFarEndVTCurrentEntry
MAX-ACCESSnot-accessible
STATUScurrentDESCRIPTION"The SONET/SDH Far End VT Current table."::={ sonetFarEndVT 1}sonetFarEndVTCurrentEntry OBJECT-TYPESYNTAX SonetFarEndVTCurrentEntry
MAX-ACCESSnot-accessibleSTATUScurrentDESCRIPTION"An entry in the SONET/SDH Far End VT Current table."INDEX{ ifIndex }::={ sonetFarEndVTCurrentTable 1}
SonetFarEndVTCurrentEntry ::=SEQUENCE{
sonetFarEndVTCurrentESs PerfCurrentCount,
sonetFarEndVTCurrentSESs PerfCurrentCount,
sonetFarEndVTCurrentCVs PerfCurrentCount,
sonetFarEndVTCurrentUASs PerfCurrentCount}sonetFarEndVTCurrentESs OBJECT-TYPESYNTAXPerfCurrentCountMAX-ACCESSread-onlySTATUScurrent
DESCRIPTION"The counter associated with the number of Far
End Errored Seconds encountered by a SONET/SDH
interface in the current 15 minute interval."::={ sonetFarEndVTCurrentEntry 1}sonetFarEndVTCurrentSESs OBJECT-TYPESYNTAXPerfCurrentCountMAX-ACCESSread-onlySTATUScurrentDESCRIPTION"The counter associated with the number of
Far End Severely Errored Seconds
encountered by a SONET/SDH VT interface
in the current 15 minute
interval."::={ sonetFarEndVTCurrentEntry 2}sonetFarEndVTCurrentCVs OBJECT-TYPESYNTAXPerfCurrentCountMAX-ACCESSread-onlySTATUScurrentDESCRIPTION"The counter associated with the number of
Far End Coding Violations reported via
the far end block error count
encountered by a
SONET/SDH VT interface
in the current 15 minute interval."::={ sonetFarEndVTCurrentEntry 3}
sonetFarEndVTCurrentUASs OBJECT-TYPESYNTAXPerfCurrentCountMAX-ACCESSread-onlySTATUScurrentDESCRIPTION"The counter associated with the number of
Far End Unavailable Seconds
encountered by a
SONET/SDH VT interface
in the current 15 minute interval."::={ sonetFarEndVTCurrentEntry 4}-- The SONET/SDH Far End VT Interval Table-- The SONET/SDH Far End VT Interval Table
-- contains various statistics
-- collected by each system over a maximum
-- of the previous 24 hours of
-- operation. The past 24 hours may be broken into 96
-- completed 15 minute intervals.
-- A system is required to store at
-- least 4 completed 15 minute interval.
-- The default value is 32 intervals.sonetFarEndVTIntervalTable OBJECT-TYPESYNTAXSEQUENCEOF SonetFarEndVTIntervalEntry
MAX-ACCESSnot-accessibleSTATUScurrentDESCRIPTION"The SONET/SDH Far End VT Interval table."::={ sonetFarEndVT 2}
sonetFarEndVTIntervalEntry OBJECT-TYPESYNTAX SonetFarEndVTIntervalEntry
MAX-ACCESSnot-accessibleSTATUScurrentDESCRIPTION"An entry in the SONET/SDH Far
End VT Interval table."INDEX{ ifIndex,
sonetFarEndVTIntervalNumber }::={ sonetFarEndVTIntervalTable 1}
SonetFarEndVTIntervalEntry ::=SEQUENCE{
sonetFarEndVTIntervalNumber Integer32,
sonetFarEndVTIntervalESs PerfIntervalCount,
sonetFarEndVTIntervalSESs PerfIntervalCount,
sonetFarEndVTIntervalCVs PerfIntervalCount,
sonetFarEndVTIntervalUASs PerfIntervalCount,
sonetFarEndVTIntervalValidData TruthValue}sonetFarEndVTIntervalNumber OBJECT-TYPESYNTAXInteger32(1..96)
MAX-ACCESSnot-accessibleSTATUScurrentDESCRIPTION"A number between 1 and 96, which identifies the
interval for which the set of statistics is available.
The interval identified by 1 is the most recently
completed 15 minute interval,
and the interval identified
by N is the interval immediately preceding the
one identified
by N-1."::={ sonetFarEndVTIntervalEntry 1}sonetFarEndVTIntervalESs OBJECT-TYPESYNTAXPerfIntervalCountMAX-ACCESSread-onlySTATUScurrentDESCRIPTION"The counter associated with the number of
Far End Errored Seconds encountered
by a SONET/SDH VT interface
in a particular 15-minute interval
in the past 24 hours."::={ sonetFarEndVTIntervalEntry 2}sonetFarEndVTIntervalSESs OBJECT-TYPESYNTAXPerfIntervalCountMAX-ACCESSread-only
STATUScurrentDESCRIPTION"The counter associated with the number of
Far End Severely Errored Seconds
encountered by a SONET/SDH VT interface
in a particular 15-minute interval
in the past 24 hours."::={ sonetFarEndVTIntervalEntry 3}sonetFarEndVTIntervalCVs OBJECT-TYPESYNTAXPerfIntervalCountMAX-ACCESSread-onlySTATUScurrentDESCRIPTION"The counter associated with the number of
Far End Coding Violations reported via
the far end block error count
encountered by a
SONET/SDH VT interface in a
particular 15-minute interval
in the past 24 hours."::={ sonetFarEndVTIntervalEntry 4}sonetFarEndVTIntervalUASs OBJECT-TYPESYNTAXPerfIntervalCountMAX-ACCESSread-onlySTATUScurrentDESCRIPTION"The counter associated with the number of
Far End Unavailable Seconds
encountered by a
SONET/SDH VT interface in a
particular 15-minute interval
in the past 24 hours."::={ sonetFarEndVTIntervalEntry 5}sonetFarEndVTIntervalValidData OBJECT-TYPESYNTAXTruthValueMAX-ACCESSread-onlySTATUScurrentDESCRIPTION"This variable indicates if the data for this
interval is valid."::={ sonetFarEndVTIntervalEntry 6}-- conformance informationsonetConformance OBJECTIDENTIFIER::={ sonetMIB 4}sonetGroups OBJECTIDENTIFIER::={ sonetConformance 1}sonetCompliances OBJECTIDENTIFIER::={ sonetConformance 2}-- deprecated compliance statementsonetCompliance MODULE-COMPLIANCESTATUSdeprecated
DESCRIPTION"The compliance statement for SONET/SDH interfaces."MODULE-- this moduleMANDATORY-GROUPS{ sonetMediumStuff, sonetSectionStuff }GROUP sonetLineStuff
DESCRIPTION"Implementation of this group is mandatory for all
SONET/SDH systems that terminate SONET/SDH Lines,
Paths or Virtual Tributaries."GROUP sonetFarEndLineStuff
DESCRIPTION"Implementation of this group is optional for all
SONET/SDH systems that terminate SONET/SDH Lines,
Paths or Virtual Tributaries, and that
provide for a far end block error (FEBE)
information at the SONET/SDH Line Layer."GROUP sonetPathStuff
DESCRIPTION"Implementation of this group is mandatory for all
SONET/SDH systems that terminate SONET/SDH
Paths or Virtual Tributaries."OBJECT sonetPathCurrentWidth
MIN-ACCESSread-onlyDESCRIPTION"Write access is not required."GROUP sonetFarEndPathStuff
DESCRIPTION
"Implementation of this group is optional for all
SONET/SDH systems that terminate SONET/SDH
Paths or Virtual Tributaries, and that process
Far End information."GROUP sonetVTStuff
DESCRIPTION"Implementation of this group is mandatory for all
SONET/SDH systems that terminate SONET/SDH Virtual
Tributaries."OBJECT sonetVTCurrentWidth
MIN-ACCESSread-onlyDESCRIPTION"Write access is not required."GROUP sonetFarEndVTStuff
DESCRIPTION"Implementation of this group is optional for all
SONET/SDH systems that terminate the SONET/SDH
floating Virtual Tributaries, and that process
Far End information."::={ sonetCompliances 1}-- current compliance statementssonetCompliance2 MODULE-COMPLIANCESTATUScurrentDESCRIPTION"The compliance statement for SONET/SDH interfaces."MODULE-- this moduleMANDATORY-GROUPS{ sonetMediumStuff2, sonetSectionStuff2 }
OBJECT sonetMediumType
MIN-ACCESSread-onlyDESCRIPTION"Write access is not required."OBJECT sonetMediumLineCoding
MIN-ACCESSread-onlyDESCRIPTION"Write access is not required."OBJECT sonetMediumLineType
MIN-ACCESSread-onlyDESCRIPTION"Write access is not required."OBJECT sonetMediumCircuitIdentifier
MIN-ACCESSread-onlyDESCRIPTION"Write access is not required."OBJECT sonetMediumLoopbackConfig
MIN-ACCESSread-onlyDESCRIPTION"Write access is not required."OBJECT sonetSESthresholdSet
MIN-ACCESSread-onlyDESCRIPTION"Write access is not required, and only one
of the enumerated values need be supported."GROUP sonetLineStuff2
DESCRIPTION"Implementation of this group is mandatory for all
SONET/SDH systems that terminate SONET/SDH Lines,
Paths or Virtual Tributaries."GROUP sonetFarEndLineStuff2
DESCRIPTION"Implementation of this group is optional for all
SONET/SDH systems that terminate SONET/SDH Lines,
Paths or Virtual Tributaries, and that
provide for a far end block error (FEBE)
information at the SONET/SDH Line Layer."GROUP sonetPathStuff2
DESCRIPTION"Implementation of this group is mandatory for all
SONET/SDH systems that terminate SONET/SDH
Paths or Virtual Tributaries."OBJECT sonetPathCurrentWidth
MIN-ACCESSread-onlyDESCRIPTION"Write access is not required."GROUP sonetFarEndPathStuff2
DESCRIPTION"Implementation of this group is optional for all
SONET/SDH systems that terminate SONET/SDH
Paths or Virtual Tributaries, and that process
Far End information."GROUP sonetVTStuff2
DESCRIPTION"Implementation of this group is mandatory for all
SONET/SDH systems that terminate SONET/SDH Virtual
Tributaries."OBJECT sonetVTCurrentWidth
MIN-ACCESSread-onlyDESCRIPTION"Write access is not required."GROUP sonetFarEndVTStuff2
DESCRIPTION"Implementation of this group is optional for all
SONET/SDH systems that terminate the SONET/SDH
floating Virtual Tributaries, and that process
Far End information."::={ sonetCompliances 2}-- units of conformance-- deprecated groupssonetMediumStuff OBJECT-GROUPOBJECTS{ sonetMediumType,
sonetMediumTimeElapsed,
sonetMediumValidIntervals,
sonetMediumLineCoding,
sonetMediumLineType,
sonetMediumCircuitIdentifier }STATUSdeprecatedDESCRIPTION"A collection of objects providing configuration
information applicable to all SONET/SDH interfaces."
::={ sonetGroups 1}sonetSectionStuff OBJECT-GROUPOBJECTS{ sonetSectionCurrentStatus,
sonetSectionCurrentESs,
sonetSectionCurrentSESs,
sonetSectionCurrentSEFSs,
sonetSectionCurrentCVs,
sonetSectionIntervalESs,
sonetSectionIntervalSESs,
sonetSectionIntervalSEFSs,
sonetSectionIntervalCVs
}STATUSdeprecatedDESCRIPTION"A collection of objects providing information
specific to SONET/SDH Section interfaces."::={ sonetGroups 2}sonetLineStuff OBJECT-GROUPOBJECTS{ sonetLineCurrentStatus,
sonetLineCurrentESs,
sonetLineCurrentSESs,
sonetLineCurrentCVs,
sonetLineCurrentUASs,
sonetLineIntervalESs,
sonetLineIntervalSESs,
sonetLineIntervalCVs,
sonetLineIntervalUASs }STATUSdeprecatedDESCRIPTION"A collection of objects providing information
specific to SONET/SDH Line interfaces."::={ sonetGroups 3}sonetFarEndLineStuff OBJECT-GROUPOBJECTS{ sonetFarEndLineCurrentESs,
sonetFarEndLineCurrentSESs,
sonetFarEndLineCurrentCVs,
sonetFarEndLineCurrentUASs,
sonetFarEndLineIntervalESs,
sonetFarEndLineIntervalSESs,
sonetFarEndLineIntervalCVs,
sonetFarEndLineIntervalUASs }STATUSdeprecatedDESCRIPTION"A collection of objects providing information
specific to SONET/SDH Line interfaces,
and maintaining Line Far End information."::={ sonetGroups 4}sonetPathStuff OBJECT-GROUPOBJECTS{ sonetPathCurrentWidth,
sonetPathCurrentStatus,
sonetPathCurrentESs,
sonetPathCurrentSESs,
sonetPathCurrentCVs,
sonetPathCurrentUASs,
sonetPathIntervalESs,
sonetPathIntervalSESs,
sonetPathIntervalCVs,
sonetPathIntervalUASs }STATUSdeprecatedDESCRIPTION"A collection of objects providing information
specific to SONET/SDH Path interfaces."::={ sonetGroups 5}sonetFarEndPathStuff OBJECT-GROUPOBJECTS{ sonetFarEndPathCurrentESs,
sonetFarEndPathCurrentSESs,
sonetFarEndPathCurrentCVs,
sonetFarEndPathCurrentUASs,
sonetFarEndPathIntervalESs,
sonetFarEndPathIntervalSESs,
sonetFarEndPathIntervalCVs,
sonetFarEndPathIntervalUASs }STATUSdeprecatedDESCRIPTION"A collection of objects providing information
specific to SONET/SDH Path interfaces,
and maintaining Path Far End information."::={ sonetGroups 6}sonetVTStuff OBJECT-GROUPOBJECTS{ sonetVTCurrentWidth,
sonetVTCurrentStatus,
sonetVTCurrentESs,
sonetVTCurrentSESs,
sonetVTCurrentCVs,
sonetVTCurrentUASs,
sonetVTIntervalESs,
sonetVTIntervalSESs,
sonetVTIntervalCVs,
sonetVTIntervalUASs }STATUSdeprecatedDESCRIPTION"A collection of objects providing information
specific to SONET/SDH VT interfaces."::={ sonetGroups 7}sonetFarEndVTStuff OBJECT-GROUPOBJECTS{ sonetFarEndVTCurrentESs,
sonetFarEndVTCurrentSESs,
sonetFarEndVTCurrentCVs,
sonetFarEndVTCurrentUASs,
sonetFarEndVTIntervalESs,
sonetFarEndVTIntervalSESs,
sonetFarEndVTIntervalCVs,
sonetFarEndVTIntervalUASs }STATUSdeprecatedDESCRIPTION"A collection of objects providing information
specific to SONET/SDH VT interfaces,
and maintaining VT Far End information."::={ sonetGroups 8}-- current groupssonetMediumStuff2 OBJECT-GROUPOBJECTS{ sonetMediumType,
sonetMediumTimeElapsed,
sonetMediumValidIntervals,
sonetMediumLineCoding,
sonetMediumLineType,
sonetMediumCircuitIdentifier,
sonetMediumInvalidIntervals,
sonetMediumLoopbackConfig,
sonetSESthresholdSet }STATUScurrentDESCRIPTION"A collection of objects providing configuration
information applicable to all SONET/SDH interfaces."::={ sonetGroups 9}
sonetSectionStuff2 OBJECT-GROUPOBJECTS{ sonetSectionCurrentStatus,
sonetSectionCurrentESs,
sonetSectionCurrentSESs,
sonetSectionCurrentSEFSs,
sonetSectionCurrentCVs,
sonetSectionIntervalESs,
sonetSectionIntervalSESs,
sonetSectionIntervalSEFSs,
sonetSectionIntervalCVs,
sonetSectionIntervalValidData }STATUScurrentDESCRIPTION"A collection of objects providing information
specific to SONET/SDH Section interfaces."::={ sonetGroups 10}sonetLineStuff2 OBJECT-GROUPOBJECTS{ sonetLineCurrentStatus,
sonetLineCurrentESs,
sonetLineCurrentSESs,
sonetLineCurrentCVs,
sonetLineCurrentUASs,
sonetLineIntervalESs,
sonetLineIntervalSESs,
sonetLineIntervalCVs,
sonetLineIntervalUASs,
sonetLineIntervalValidData }STATUScurrentDESCRIPTION"A collection of objects providing information
specific to SONET/SDH Line interfaces."::={ sonetGroups 11}sonetPathStuff2 OBJECT-GROUPOBJECTS{ sonetPathCurrentWidth,
sonetPathCurrentStatus,
sonetPathCurrentESs,
sonetPathCurrentSESs,
sonetPathCurrentCVs,
sonetPathCurrentUASs,
sonetPathIntervalESs,
sonetPathIntervalSESs,
sonetPathIntervalCVs,
sonetPathIntervalUASs,
sonetPathIntervalValidData }STATUScurrentDESCRIPTION"A collection of objects providing information
specific to SONET/SDH Path interfaces."::={ sonetGroups 12}
sonetVTStuff2 OBJECT-GROUPOBJECTS{ sonetVTCurrentWidth,
sonetVTCurrentStatus,
sonetVTCurrentESs,
sonetVTCurrentSESs,
sonetVTCurrentCVs,
sonetVTCurrentUASs,
sonetVTIntervalESs,
sonetVTIntervalSESs,
sonetVTIntervalCVs,
sonetVTIntervalUASs,
sonetVTIntervalValidData }STATUScurrentDESCRIPTION"A collection of objects providing information
specific to SONET/SDH VT interfaces."::={ sonetGroups 13}sonetFarEndLineStuff2 OBJECT-GROUPOBJECTS{ sonetFarEndLineCurrentESs,
sonetFarEndLineCurrentSESs,
sonetFarEndLineCurrentCVs,
sonetFarEndLineCurrentUASs,
sonetFarEndLineIntervalESs,
sonetFarEndLineIntervalSESs,
sonetFarEndLineIntervalCVs,
sonetFarEndLineIntervalUASs,
sonetFarEndLineIntervalValidData }STATUScurrentDESCRIPTION"A collection of objects providing information
specific to SONET/SDH Line interfaces,
and maintaining Line Far End information."::={ sonetGroups 14}sonetFarEndPathStuff2 OBJECT-GROUPOBJECTS{ sonetFarEndPathCurrentESs,
sonetFarEndPathCurrentSESs,
sonetFarEndPathCurrentCVs,
sonetFarEndPathCurrentUASs,
sonetFarEndPathIntervalESs,
sonetFarEndPathIntervalSESs,
sonetFarEndPathIntervalCVs,
sonetFarEndPathIntervalUASs,
sonetFarEndPathIntervalValidData }STATUScurrentDESCRIPTION"A collection of objects providing information
specific to SONET/SDH Path interfaces,
and maintaining Path Far End information."::={ sonetGroups 15}sonetFarEndVTStuff2 OBJECT-GROUP
OBJECTS{ sonetFarEndVTCurrentESs,
sonetFarEndVTCurrentSESs,
sonetFarEndVTCurrentCVs,
sonetFarEndVTCurrentUASs,
sonetFarEndVTIntervalESs,
sonetFarEndVTIntervalSESs,
sonetFarEndVTIntervalCVs,
sonetFarEndVTIntervalUASs,
sonetFarEndVTIntervalValidData }STATUScurrentDESCRIPTION"A collection of objects providing information
specific to SONET/SDH VT interfaces,
and maintaining VT Far End information."::={ sonetGroups 16}END